Written by: Ashton A. Prince, DMD
The evolution of dental materials science continues to redefine what is possible at the chairside level. Since the early integration of CAD/CAM into restorative dentistry, as dental professionals we have witnessed dramatic improvements in the precision, aesthetics, and efficiency with which indirect restorations can be quickly designed and delivered.1
As CAD/CAM has confirmed its valuable daily use over the past years, what was once a technology reserved for the clinical laboratory has become a cornerstone of the modern, productivity-focused practice, and with that expansion has come an understandable demand for materials that rise to meet it.2
As clinicians, we ask a great deal of our restorative materials every day. We request minimal preparation thicknesses that support conservation of tooth structure. We want surfaces that will not abrade opposing enamel. We need restorations that integrate visually with surrounding dentition so seamlessly that the word “restoration” maintains its full clinical meaning of “a return to what was once there,” rather than an uncomfortable replacement.
The Evolving CAD/CAM Materials Landscape
This grouping of indirect restorative block options is made up of several distinct material families, each with established clinical applications and trade-offs that we as clinicians have learned to navigate.3 Feldspathic and leucite-reinforced glass ceramics established the early aesthetic benchmark for milled restorations. Their light-handling properties were clinically impressive, but their inherent brittleness limited their application and demanded exact preparations and cementation protocols. Lithium disilicate, most broadly represented by IPS e.max CAD (Ivoclar), became the standard against which most aesthetic ceramic materials are still measured. With flexural strengths in the range of 360 to 400 MPa and optical properties well suited to both anterior and posterior applications, lithium disilicate continues to be the material of choice for a wide range of single-unit cases in many offices.
Zirconia, in its various generations, has taken an alternate developmental path. Early formulations prioritized strength at the expense of aesthetics. More recent advances in multi-layer and high-translucency formulations have addressed many of the opacity concerns, producing zirconia options appropriate for a broader range of cosmetic applications.4
Polymer-infiltrated ceramic and hybrid ceramic materials introduced a different design philosophy altogether. This grouping includes materials such as VITA Enamic (VITA North America) and 3M Lava Ultimate (Solventum). These materials were engineered to flex slightly under load and compression, mimicking the behavior of natural tooth structure and reducing the risk of fracture and opposing-arch wear associated with harder ceramics.5 Each of these categories serves a range of clinical needs and allows clinicians to truly customize the treatment options being offered to patients based on the desires of the patient and the clinical demands of the case. A new restorative block to consider is the Ceramir CAD/CAM Block (Directa USA). At the foundation of the Ceramir block’s clinical performance is a patented laser sintering manufacturing process. According to the manufacturer, this technology differs from conventional ceramic pressing or sintering methods in the precision with which it controls the material’s internal microstructure, producing a block with a high degree of internal consistency that enhances the mechanical properties.
One of the most immediately relevant clinical properties of hybrid-ceramic materials is their polishability. When finished with standard chairside instruments and polishing systems, the restorations achieve a high-gloss surface that rivals the appearance of externally glazed ceramics without the need for furnace cycling. For practices operating under a same-day delivery model, this eliminates a significant time-consuming step from the workflow.
In contrast to a glazed surface that can be very aggressive to an opposing surface, the polished surface of the hybrid ceramic blocks demonstrates non-abrasive behavior against opposing dentition. In addition, these more translucent materials exhibit what clinicians have come to describe as a chameleon effect. Under clinical lighting conditions, this translucency allows the restoration to blend into its environment in a manner that can make it difficult to distinguish from adjacent natural tooth structure. Notably, the new material, Ceramir, includes both zinc oxide and fluoride. Zinc oxide has demonstrated antimicrobial properties in dental restorative research, with studies showing meaningful reductions in bacterial biofilm formation when incorporated into restorative materials.6
CASE REPORT
Diagnosis and Treatment Planning
A 44-year-old female patient presented with a failed occlusal restoration, which had resulted in a compromised supportive margin wall on a maxillary first molar. Clinical and radiographic examination revealed that the existing large composite restoration, which had been placed approximately 20 years prior, now presented with recurrent decay and a high risk of fracturing under the restoration (Figures 1 and 2). The patient demonstrated no significant medical history, maintained adequate oral hygiene, and presented with a clinically stable endodontic prognosis. Radiographic evaluation and thermal testing of the tooth confirmed pulpal vitality and adequate periodontal bone levels.
Figure 1. Initial presentation of tooth No. 3 with an existing composite resin that had been present for at least 25 years. Recurrent decay and fracture lines viewed clinically.
Figure 2a. Bitewing view of the tooth showing the extent of the recurrent decay and base of the existing restoration.
Figure 2b. Periapical radiograph view of tooth No. 3 to confirm endodontic health and prognosis prior to restoring the tooth.
Following discussion of treatment options—including conservative restoration replacement and a partial-coverage CAD/CAM ceramic restoration designed and delivered in a single appointment—the patient was informed of the more complex clinical findings and potential need for more extensive procedures. Conservative measures were considered first due to the clinical presentation of the occlusal surface. The patient was also given the opportunity to ask questions and was provided with the always extremely important informed consent prior to treatment. The decision was made to proceed with removal of the existing decay, further adjustments to the tooth, and placement of a more definitive ceramic onlay for a more predictable restorative prognosis as compared to a very large composite restoration.
Operative Appointment
Local anesthesia was administered, and the decay was removed , stopping short of the pulp and performing vital pulp therapy with selectivecaries removal. Photographs were taken of the tooth, and following clinical assessment, an indirect pulp cap was placed using Lime-Lite Enhanced (Pulpdent) liner prior to finalizing the preparation (Figure 3). The distal marginal ridge was then included in the tooth preparation with approximately 1.2 mm of axial reduction. A smooth chamfer margin was placed supragingivally on the distal, occlusal, and lingual surfaces. All line angles were rounded and surfaces refined with a fine diamond (Figure 4).
Figure 3. Initial decay excavation and placement of pulpal liner to assist in maintenance of pulpal health. View of the fracture line on the DL cusp is more evident and started the discussion with the patient to extend the preparation of the tooth for the restorative onlay.
Figure 4. Initial clearing of the distal margin as an extension of the preparation to provide a more durable and structurally sound restoration.
Preparation of the natural tooth for cementation consisted of micro air abrasion of the tooth with 30-µm aluminum oxide powder using the Microetcher II Sandblaster (Zest), a 15-second etching of the enamel with 37% phosphoric acid, and rinsing and drying of the tooth. Clearfil Universal Bond Quick 2 (Kuraray) was used to seal the dentinal tubules in an IDS (Immediate Dentin Sealing) technique, and a layer of CLEARFIL Majesty ES Flow Universal (Kuraray) was used to provide a better foundation for the restoration (Figure 5). An intraoral scan was acquired using the CEREC Primescan digital impression system (Dentsply Sirona), capturing the preparation, opposing arch, and buccal bite registration (Figures 6 and 7). The partial coverage crown or onlay was designed with attention given to occlusal anatomy, functional wear patterns, interproximal contacts, and natural emergence profile.
Figure 5. Air abrasion of the tooth as a final step to prepare the tooth for scanning and placement of the restoration.
Figure 6. View of the preparation from scanning to see the path of insertion and confirm no undercuts are present.
Figure 7. Lingual view of the scan to see the minimal extension of a margin along the distal margin and around the DL cusp.
A T-block Ceramir restoration block was selected due to the need for greater translucency, allowing for the shade to correspond to the patient’s natural dentition. The material was placed in the CEREC MCXL milling unit (Dentsply Sirona) and fabricated in approximately 6 minutes. Following milling, the restoration was placed upon the prepared tooth to check for proper contours and contacts, which was further confirmed radiographically (Figure 8). Marginal adaptation was excellent, and the disappearing chameleon effect was evident. Occlusal contacts were adjusted using the TrollFoil articulating paper (Directa USA) and a slow-set high-speed handpiece with a Football 379 fine-grit diamond bur. The intaglio surface of the restoration was air-abraded with 50-µm aluminum oxide powder per the manufacturer’s recommendations. The exterior of the restoration was polished chairside to a high-gloss finish using the A.S.A.P. polishers from Clinician’s Choice as well as Enamelize polishing paste (Cosmedent) and a felt polishing wheel.
Figure 8. Radiograph of the restoration at the time of seating.
Because areas of the restoration were thicker than the suggested 2 mm clinical reach of most light-curing devices, a dual-cure resin cement (G-CEM ONE [GC America]) was selected. This involved placement of the GC Adhesive Enhancing Primer (AEP) with a 10-second scrub, air thinning of the material, then placement of the translucent resin cement and seating of the prepared restoration. Downward pressure on the occlusal surface was applied to allow for initial self-curing over the first 30 seconds. As the gel state began to form, excess material was removed with a microbrush and dental explorer. Four minutes of self-curing was permitted, although the time could have been quickly advanced with a 20-second light curing from multiple directions. The TrollFoil articulating paper was used to confirm the final occlusal fit once again, and an intraoral polishing was completed with the A.S.A.P. polishers as a final step (Figure 9).
Figure 9. Final cementation of the restoration with a view of the blending shade and adaptation of the material to the existing enamel.
Postoperative Results
At the 2-week postoperative examination, the patient reported no thermal sensitivity and was very satisfied with the aesthetic result and the occlusal fit. At the 6-month recall appointment, marginal gingival tissues remained healthy and without inflammation, and occlusal contacts were stable. Assessment of the restoration at the 2-year mark showed the restoration to be without clinical or radiographic complications, and the opposing dentition did not show signs of wear, as the material surface did not include a glaze. As a bonus, to this day the restored tooth remains clinically indistinguishable from adjacent natural teeth with a maintained polished appearance (Figures 10 and 11).
Figure 10. Two-year postoperative image of tooth No. 3. Minor breakdown on the occlusal surface not associated with the onlay restoration. Due to the nature of the material, the area can be excavated (if desired), and a simple composite restoration can be used to restore the area.
Figure 11. Two-year post-op radiograph to confirm material longevity.
Closing Comments
The CAD/CAM restorative materials category continues to mature at a rapid pace that rewards clinicians who remain engaged with its development. Even with longevity concerns due to the lack of long-term data, the trend toward more biomimetic materials is very promising. The Ceramir CAD/CAM Block represents a thoughtful and clinically meaningful contribution to that landscape. For single-unit anterior crowns, posterior crowns, and overlay or onlay preparations where aesthetic priority and biological compatibility are as important as mechanical performance, the Ceramir block demonstrates favorable outcomes. It does not aim to replace zirconia in high-demand structural applications or lithium disilicate in cases where specific mechanical demands are required. Rather, it is best designed for indirect restorations needing an aesthetic touch in areas where mechanical loads and forces are light, and it does so while bringing a biological dimension to the restoration that the dental field is actively pursuing.
As materials science continues to advance the possibilities available to us as restorative clinicians, the standard by which we define an ideal restoration must also advance. The ability to use the word “restore” with full clinical intent is becoming more of a reality. As we become more conservative in our procedures and more biologic in our materials, we are also striving to continue achieving aesthetic results for our patients. Our treatments are more customizable, and the standard by which we define an ideal restoration continues to advance accordingly—making this an exciting time to be a part of the restorative field in dentistry.
REFERENCES
1. Fasbinder DJ. Clinical performance of chairside CAD/CAM restorations. J Am Dent Assoc. 2006;137(Suppl):22S–31S.
2. Mörmann WH. The evolution of the CEREC system. J Am Dent Assoc. 2006;137(Suppl):7S–13S.
3. Gracis S, Thompson VP, Ferencz JL, et al. A new classification system for all-ceramic and ceramic-like restorative materials. Int J Prosthodont. 2015;28:227–235.
4. Raigrodski AJ, Hillstead MB, Meng GK, et al. Survival and complications of zirconia-based fixed dental prostheses: a systematic review. J Prosthet Dent. 2012;107:170–177.
5. Coldea A, Swain MV, Thiel N. Mechanical properties of polymer-infiltrated-ceramic-network materials. Dent Mater. 2013;29:419–426.
6. Aydin Sevinç B, Hanley L. Antibacterial activity of dental composites containing zinc oxide nanoparticles. J Biomed Mater Res B Appl Biomater. 2010;94(1):22–31.
ABOUT THE AUTHOR
Dr. Prince maintains a general dental practice in St. George, Utah. He also serves as the chief editor for DENTAL ADVISOR. He can be reached at [email protected].
Disclosure: Ashton A Prince, DMD, has no financial interest in any of the companies or products mentioned in this article.

Leave a Reply